summaryrefslogtreecommitdiff
path: root/share/man/man4
diff options
context:
space:
mode:
authorcvs2svn <cvs2svn@FreeBSD.org>2000-09-25 21:57:54 +0000
committercvs2svn <cvs2svn@FreeBSD.org>2000-09-25 21:57:54 +0000
commit2641b0c407077fa8c3032d87d15ac6a103b0ed1b (patch)
tree97e7da54e454c6cb23ca18813708e5c453e8de9f /share/man/man4
parent57293fdc2cfdd01d9d5e32d0e5243669d7e006e9 (diff)
Notes
Diffstat (limited to 'share/man/man4')
-rw-r--r--share/man/man4/mly.4256
1 files changed, 0 insertions, 256 deletions
diff --git a/share/man/man4/mly.4 b/share/man/man4/mly.4
deleted file mode 100644
index 40e6e4bbe032e..0000000000000
--- a/share/man/man4/mly.4
+++ /dev/null
@@ -1,256 +0,0 @@
-.\"
-.\" Copyright (c) 2000 Michael Smith
-.\" Copyright (c) 2000 BSDi
-.\" All rights reserved.
-.\"
-.\" Redistribution and use in source and binary forms, with or without
-.\" modification, are permitted provided that the following conditions
-.\" are met:
-.\" 1. Redistributions of source code must retain the above copyright
-.\" notice, this list of conditions and the following disclaimer.
-.\" 2. The name of the author may not be used to endorse or promote products
-.\" derived from this software without specific prior written permission
-.\"
-.\" THIS SOFTWARE IS PROVIDED BY THE AUTHOR ``AS IS'' AND ANY EXPRESS OR
-.\" IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES
-.\" OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED.
-.\" IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT, INDIRECT,
-.\" INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
-.\" NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
-.\" DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
-.\" THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
-.\" (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF
-.\" THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
-.\"
-.\" $FreeBSD$
-.\"
-.Dd August 22, 2000
-.Dt MLY 4
-.Os
-.Sh NAME
-.Nm mly
-.Nd Mylex AcceleRAID/eXtremeRAID family driver
-.Sh SYNOPSIS
-.Cd device pci
-.Cd device mly
-.Cd device scbus
-.Cd device da
-.Sh DESCRIPTION
-The
-.Nm
-driver provides support for Mylex AcceleRAID and eXtremeRAID-family
-PCI to SCSI RAID controllers with version 6.00 and later
-firmware.
-Supported controllers include:
-.Bl -bullet
-.It
-AcceleRAID 160
-.It
-AcceleRAID 170
-.It
-AcceleRAID 352
-.It
-eXtremeRAID 2000
-.It
-eXtremeRAID 3000
-.El
-.Pp
-Compatible Mylex controllers not listed should work, but have not been
-verified.
-.Pp
-Logical devices (array drives) attached to the controller are presented
-to the SCSI subsystem as though they were direct-access devices on a
-virtual SCSI bus.
-Physical devices which are not claimed by a logical
-device are presented on SCSI channels which match the physical channels
-on the controller.
-.Sh DIAGNOSTICS
-.Ss Controller initialisation phase
-.Bl -diag
-.It "mly%d: controller initialisation started"
-.It "mly%d: initialisation complete"
-.Pp
-The controller firmware has started initialisation.
-Normally this process is performed by the controller BIOS,
-but the driver may need
-to do this in cases where the BIOS has failed, or is not compatible
-(e.g. on non-x86 systems).
-.It "mly%d: drive spinup in progress"
-.Pp
-Drive startup is in progress; this may take several minutes.
-.It "mly%d: mirror race recovery failed, one or more drives offline"
-.It "mly%d: mirror race recovery in progress"
-.It "mly%d: mirror race recovery on a critical drive"
-.Pp
-These error codes are undocumented.
-.It "mly%d: FATAL MEMORY PARITY ERROR"
-.Pp
-Firmware detected a fatal memory error; the driver will not attempt to
-attach to this controller.
-.It "mly%d: unknown initialisation code %x"
-.Pp
-An unknown error occurred during initialisation; it will be ignored.
-.El
-.Ss Driver initialisation/shutdown phase
-.Bl -diag
-.It "mly%d: can't enable busmaster feature"
-.It "mly%d: memory window not available"
-.It "mly%d: can't allocate register window"
-.It "mly%d: can't allocate interrupt"
-.It "mly%d: can't set up interrupt"
-.Pp
-The system's PCI BIOS has not correctly configured the controller's
-PCI interface; initialisation has failed and the driver will not
-attach to this controller.
-.It "mly%d: can't allocate parent DMA tag"
-.It "mly%d: can't allocate buffer DMA tag"
-.It "mly%d: can't allocate command packet DMA tag"
-.It "mly%d: can't allocate scatter/gather DMA tag"
-.It "mly%d: can't allocate s/g table"
-.It "mly%d: can't allocate memory mailbox DMA tag"
-.It "mly%d: can't allocate memory mailbox"
-.Pp
-A resource allocation error occurred while initialising the driver;
-initialisation has failed and the driver will not attach to this
-controller.
-.It "mly%d: BTL rescan result corrupted"
-.Pp
-The results of a scan for an attached device were corrupted.
-One or more devices may not be correctly reported.
-.It "mly%d: flushing cache..."
-.Pp
-The controller cache is being flushed prior to detach or shutdown.
-.El
-.Ss Operational diagnostics
-.Bl -diag
-.It "mly%d: physical device %d:%d online"
-.It "mly%d: physical device %d:%d standby"
-.It "mly%d: physical device %d:%d automatic rebuild started"
-.It "mly%d: physical device %d:%d manual rebuild started"
-.It "mly%d: physical device %d:%d rebuild completed"
-.It "mly%d: physical device %d:%d rebuild cancelled"
-.It "mly%d: physical device %d:%d rebuild failed for unknown reasons"
-.It "mly%d: physical device %d:%d rebuild failed due to new physical device"
-.It "mly%d: physical device %d:%d rebuild failed due to logical drive failure"
-.It "mly%d: physical device %d:%d found"
-.It "mly%d: physical device %d:%d gone"
-.It "mly%d: physical device %d:%d unconfigured"
-.It "mly%d: physical device %d:%d expand capacity started"
-.It "mly%d: physical device %d:%d expand capacity completed"
-.It "mly%d: physical device %d:%d expand capacity failed"
-.It "mly%d: physical device %d:%d parity error"
-.It "mly%d: physical device %d:%d soft error"
-.It "mly%d: physical device %d:%d miscellaneous error"
-.It "mly%d: physical device %d:%d reset"
-.It "mly%d: physical device %d:%d active spare found"
-.It "mly%d: physical device %d:%d warm spare found"
-.It "mly%d: physical device %d:%d initialization started"
-.It "mly%d: physical device %d:%d initialization completed"
-.It "mly%d: physical device %d:%d initialization failed"
-.It "mly%d: physical device %d:%d initialization cancelled"
-.It "mly%d: physical device %d:%d write recovery failed"
-.It "mly%d: physical device %d:%d scsi bus reset failed"
-.It "mly%d: physical device %d:%d double check condition"
-.It "mly%d: physical device %d:%d device cannot be accessed"
-.It "mly%d: physical device %d:%d gross error on scsi processor"
-.It "mly%d: physical device %d:%d bad tag from device"
-.It "mly%d: physical device %d:%d command timeout"
-.It "mly%d: physical device %d:%d system reset"
-.It "mly%d: physical device %d:%d busy status or parity error"
-.It "mly%d: physical device %d:%d host set device to failed state"
-.It "mly%d: physical device %d:%d selection timeout"
-.It "mly%d: physical device %d:%d scsi bus phase error"
-.It "mly%d: physical device %d:%d device returned unknown status"
-.It "mly%d: physical device %d:%d device not ready"
-.It "mly%d: physical device %d:%d device not found at startup"
-.It "mly%d: physical device %d:%d COD write operation failed"
-.It "mly%d: physical device %d:%d BDT write operation failed"
-.It "mly%d: physical device %d:%d missing at startup"
-.It "mly%d: physical device %d:%d start rebuild failed due to physical drive too small"
-.It "mly%d: physical device %d:%d sense data received"
-.It "mly%d: sense key %d asc %02x ascq %02x"
-.It "mly%d: info %4D csi %4D"
-.It "mly%d: physical device %d:%d offline"
-.It "mly%d: sense key %d asc %02x ascq %02x"
-.It "mly%d: info %4D csi %4D"
-.Pp
-The reported event refers to the physical device at the given channel:target
-address.
-.It "mly%d: logical device %d (%s) consistency check started"
-.It "mly%d: logical device %d (%s) consistency check completed"
-.It "mly%d: logical device %d (%s) consistency check cancelled"
-.It "mly%d: logical device %d (%s) consistency check completed with errors"
-.It "mly%d: logical device %d (%s) consistency check failed due to logical drive failure"
-.It "mly%d: logical device %d (%s) consistency check failed due to physical device failure"
-.It "mly%d: logical device %d (%s) automatic rebuild started"
-.It "mly%d: logical device %d (%s) manual rebuild started"
-.It "mly%d: logical device %d (%s) rebuild completed"
-.It "mly%d: logical device %d (%s) rebuild cancelled"
-.It "mly%d: logical device %d (%s) rebuild failed for unknown reasons"
-.It "mly%d: logical device %d (%s) rebuild failed due to new physical device"
-.It "mly%d: logical device %d (%s) rebuild failed due to logical drive failure"
-.It "mly%d: logical device %d (%s) offline"
-.It "mly%d: logical device %d (%s) critical"
-.It "mly%d: logical device %d (%s) online"
-.It "mly%d: logical device %d (%s) initialization started"
-.It "mly%d: logical device %d (%s) initialization completed"
-.It "mly%d: logical device %d (%s) initialization cancelled"
-.It "mly%d: logical device %d (%s) initialization failed"
-.It "mly%d: logical device %d (%s) found"
-.It "mly%d: logical device %d (%s) gone"
-.It "mly%d: logical device %d (%s) expand capacity started"
-.It "mly%d: logical device %d (%s) expand capacity completed"
-.It "mly%d: logical device %d (%s) expand capacity failed"
-.It "mly%d: logical device %d (%s) bad block found"
-.It "mly%d: logical device %d (%s) size changed"
-.It "mly%d: logical device %d (%s) type changed"
-.It "mly%d: logical device %d (%s) bad data block found"
-.It "mly%d: logical device %d (%s) read of data block in bdt"
-.It "mly%d: logical device %d (%s) write back data for disk block lost"
-.Pp
-The event report will include the name of the SCSI device which has
-attached to the device if possible.
-.It "mly%d: enclosure %d fan %d failed"
-.It "mly%d: enclosure %d fan %d ok"
-.It "mly%d: enclosure %d fan %d not present"
-.It "mly%d: enclosure %d power supply %d failed"
-.It "mly%d: enclosure %d power supply %d ok"
-.It "mly%d: enclosure %d power supply %d not present"
-.It "mly%d: enclosure %d temperature sensor %d failed"
-.It "mly%d: enclosure %d temperature sensor %d critical"
-.It "mly%d: enclosure %d temperature sensor %d ok"
-.It "mly%d: enclosure %d temperature sensor %d not present"
-.It "mly%d: enclosure %d unit %d access critical"
-.It "mly%d: enclosure %d unit %d access ok"
-.It "mly%d: enclosure %d unit %d access offline"
-.Pp
-These events refer to external enclosures by number.
-The driver does not attempt to name the enclosures.
-.It "mly%d: controller cache write back error"
-.It "mly%d: controller battery backup unit found"
-.It "mly%d: controller battery backup unit charge level low"
-.It "mly%d: controller battery backup unit charge level ok"
-.It "mly%d: controller installation aborted"
-.It "mly%d: controller mirror race recovery in progress"
-.It "mly%d: controller mirror race on critical drive"
-.It "mly%d: controller memory soft ecc error"
-.It "mly%d: controller memory hard ecc error"
-.It "mly%d: controller battery backup unit failed"
-.Pp
-These events report controller status changes.
-.El
-.Sh BUGS
-The driver does not yet provide an external management interface.
-.Pp
-Enclosures are not named or otherwise identified in event messages.
-.Sh AUTHORS
-The
-.Nm
-driver was written by
-.An Michael Smith
-.Aq msmith@FreeBSD.org .
-.Pp
-This manual page was written by
-.An Michael Smith
-.Aq msmith@FreeBSD.org .
-