summaryrefslogtreecommitdiff
path: root/secure/lib/libcrypto/man/X509_NAME_ENTRY_get_object.3
diff options
context:
space:
mode:
Diffstat (limited to 'secure/lib/libcrypto/man/X509_NAME_ENTRY_get_object.3')
-rw-r--r--secure/lib/libcrypto/man/X509_NAME_ENTRY_get_object.363
1 files changed, 32 insertions, 31 deletions
diff --git a/secure/lib/libcrypto/man/X509_NAME_ENTRY_get_object.3 b/secure/lib/libcrypto/man/X509_NAME_ENTRY_get_object.3
index 5256605e6dfb1..e29a93c6e4213 100644
--- a/secure/lib/libcrypto/man/X509_NAME_ENTRY_get_object.3
+++ b/secure/lib/libcrypto/man/X509_NAME_ENTRY_get_object.3
@@ -1,4 +1,4 @@
-.\" Automatically generated by Pod::Man 4.09 (Pod::Simple 3.35)
+.\" Automatically generated by Pod::Man 4.10 (Pod::Simple 3.35)
.\"
.\" Standard preamble:
.\" ========================================================================
@@ -54,16 +54,20 @@
.\" Avoid warning from groff about undefined register 'F'.
.de IX
..
-.if !\nF .nr F 0
-.if \nF>0 \{\
-. de IX
-. tm Index:\\$1\t\\n%\t"\\$2"
+.nr rF 0
+.if \n(.g .if rF .nr rF 1
+.if (\n(rF:(\n(.g==0)) \{\
+. if \nF \{\
+. de IX
+. tm Index:\\$1\t\\n%\t"\\$2"
..
-. if !\nF==2 \{\
-. nr % 0
-. nr F 2
+. if !\nF==2 \{\
+. nr % 0
+. nr F 2
+. \}
. \}
.\}
+.rr rF
.\"
.\" Accent mark definitions (@(#)ms.acc 1.5 88/02/08 SMI; from UCB 4.2).
.\" Fear. Run. Save yourself. No user-serviceable parts.
@@ -129,7 +133,7 @@
.\" ========================================================================
.\"
.IX Title "X509_NAME_ENTRY_GET_OBJECT 3"
-.TH X509_NAME_ENTRY_GET_OBJECT 3 "2018-11-20" "1.1.1a" "OpenSSL"
+.TH X509_NAME_ENTRY_GET_OBJECT 3 "2019-02-26" "1.1.1b" "OpenSSL"
.\" For nroff, turn off justification. Always turn off hyphenation; it makes
.\" way too many mistakes in technical documents.
.if n .ad l
@@ -160,31 +164,28 @@ X509_NAME_ENTRY_get_object, X509_NAME_ENTRY_get_data, X509_NAME_ENTRY_set_object
.Ve
.SH "DESCRIPTION"
.IX Header "DESCRIPTION"
-\&\fIX509_NAME_ENTRY_get_object()\fR retrieves the field name of \fBne\fR in
+\&\fBX509_NAME_ENTRY_get_object()\fR retrieves the field name of \fBne\fR in
and \fB\s-1ASN1_OBJECT\s0\fR structure.
.PP
-\&\fIX509_NAME_ENTRY_get_data()\fR retrieves the field value of \fBne\fR in
+\&\fBX509_NAME_ENTRY_get_data()\fR retrieves the field value of \fBne\fR in
and \fB\s-1ASN1_STRING\s0\fR structure.
.PP
-\&\fIX509_NAME_ENTRY_set_object()\fR sets the field name of \fBne\fR to \fBobj\fR.
+\&\fBX509_NAME_ENTRY_set_object()\fR sets the field name of \fBne\fR to \fBobj\fR.
.PP
-\&\fIX509_NAME_ENTRY_set_data()\fR sets the field value of \fBne\fR to string type
+\&\fBX509_NAME_ENTRY_set_data()\fR sets the field value of \fBne\fR to string type
\&\fBtype\fR and value determined by \fBbytes\fR and \fBlen\fR.
.PP
-\&\fIX509_NAME_ENTRY_create_by_txt()\fR, \fIX509_NAME_ENTRY_create_by_NID()\fR
-and \fIX509_NAME_ENTRY_create_by_OBJ()\fR create and return an
+\&\fBX509_NAME_ENTRY_create_by_txt()\fR, \fBX509_NAME_ENTRY_create_by_NID()\fR
+and \fBX509_NAME_ENTRY_create_by_OBJ()\fR create and return an
\&\fBX509_NAME_ENTRY\fR structure.
.SH "NOTES"
.IX Header "NOTES"
-\&\fIX509_NAME_ENTRY_get_object()\fR and \fIX509_NAME_ENTRY_get_data()\fR can be
+\&\fBX509_NAME_ENTRY_get_object()\fR and \fBX509_NAME_ENTRY_get_data()\fR can be
used to examine an \fBX509_NAME_ENTRY\fR function as returned by
-\&\fIX509_NAME_get_entry()\fR for example.
+\&\fBX509_NAME_get_entry()\fR for example.
.PP
-\&\fIX509_NAME_ENTRY_create_by_txt()\fR, \fIX509_NAME_ENTRY_create_by_NID()\fR,
-and \fIX509_NAME_ENTRY_create_by_OBJ()\fR create and return an
-.PP
-\&\fIX509_NAME_ENTRY_create_by_txt()\fR, \fIX509_NAME_ENTRY_create_by_OBJ()\fR,
-\&\fIX509_NAME_ENTRY_create_by_NID()\fR and \fIX509_NAME_ENTRY_set_data()\fR
+\&\fBX509_NAME_ENTRY_create_by_txt()\fR, \fBX509_NAME_ENTRY_create_by_OBJ()\fR,
+\&\fBX509_NAME_ENTRY_create_by_NID()\fR and \fBX509_NAME_ENTRY_set_data()\fR
are seldom used in practice because \fBX509_NAME_ENTRY\fR structures
are almost always part of \fBX509_NAME\fR structures and the
corresponding \fBX509_NAME\fR functions are typically used to
@@ -192,27 +193,27 @@ create and add new entries in a single operation.
.PP
The arguments of these functions support similar options to the similarly
named ones of the corresponding \fBX509_NAME\fR functions such as
-\&\fIX509_NAME_add_entry_by_txt()\fR. So for example \fBtype\fR can be set to
-\&\fB\s-1MBSTRING_ASC\s0\fR but in the case of \fIX509_set_data()\fR the field name must be
+\&\fBX509_NAME_add_entry_by_txt()\fR. So for example \fBtype\fR can be set to
+\&\fB\s-1MBSTRING_ASC\s0\fR but in the case of \fBX509_set_data()\fR the field name must be
set first so the relevant field information can be looked up internally.
.SH "RETURN VALUES"
.IX Header "RETURN VALUES"
-\&\fIX509_NAME_ENTRY_get_object()\fR returns a valid \fB\s-1ASN1_OBJECT\s0\fR structure if it is
+\&\fBX509_NAME_ENTRY_get_object()\fR returns a valid \fB\s-1ASN1_OBJECT\s0\fR structure if it is
set or \s-1NULL\s0 if an error occurred.
.PP
-\&\fIX509_NAME_ENTRY_get_data()\fR returns a valid \fB\s-1ASN1_STRING\s0\fR structure if it is set
+\&\fBX509_NAME_ENTRY_get_data()\fR returns a valid \fB\s-1ASN1_STRING\s0\fR structure if it is set
or \s-1NULL\s0 if an error occurred.
.PP
-\&\fIX509_NAME_ENTRY_set_object()\fR and \fIX509_NAME_ENTRY_set_data()\fR return 1 on success
+\&\fBX509_NAME_ENTRY_set_object()\fR and \fBX509_NAME_ENTRY_set_data()\fR return 1 on success
or 0 on error.
.PP
-\&\fIX509_NAME_ENTRY_create_by_txt()\fR, \fIX509_NAME_ENTRY_create_by_NID()\fR and
-\&\fIX509_NAME_ENTRY_create_by_OBJ()\fR return a valid \fBX509_NAME_ENTRY\fR on success or
+\&\fBX509_NAME_ENTRY_create_by_txt()\fR, \fBX509_NAME_ENTRY_create_by_NID()\fR and
+\&\fBX509_NAME_ENTRY_create_by_OBJ()\fR return a valid \fBX509_NAME_ENTRY\fR on success or
\&\s-1NULL\s0 if an error occurred.
.SH "SEE ALSO"
.IX Header "SEE ALSO"
-\&\fIERR_get_error\fR\|(3), \fId2i_X509_NAME\fR\|(3),
-\&\fIOBJ_nid2obj\fR\|(3)
+\&\fBERR_get_error\fR\|(3), \fBd2i_X509_NAME\fR\|(3),
+\&\fBOBJ_nid2obj\fR\|(3)
.SH "COPYRIGHT"
.IX Header "COPYRIGHT"
Copyright 2002\-2018 The OpenSSL Project Authors. All Rights Reserved.