+* Maxim MAX8997 Voltage and Current Regulator
+
+The Maxim MAX8997 is a multi-function device which includes voltage and
+current regulators, rtc, charger controller and other sub-blocks. It is
+interfaced to the host controller using a i2c interface. Each sub-block is
+addressed by the host system using different i2c slave address. This document
+describes the bindings for 'pmic' sub-block of max8997.
+
+Required properties:
+- compatible: Should be "maxim,max8997-pmic".
+- reg: Specifies the i2c slave address of the pmic block. It should be 0x66.
+
+- max8997,pmic-buck1-dvs-voltage: A set of 8 voltage values in micro-volt (uV)
+ units for buck1 when changing voltage using gpio dvs. Refer to [1] below
+ for additional information.
+
+- max8997,pmic-buck2-dvs-voltage: A set of 8 voltage values in micro-volt (uV)
+ units for buck2 when changing voltage using gpio dvs. Refer to [1] below
+ for additional information.
+
+- max8997,pmic-buck5-dvs-voltage: A set of 8 voltage values in micro-volt (uV)
+ units for buck5 when changing voltage using gpio dvs. Refer to [1] below
+ for additional information.
+
+[1] If none of the 'max8997,pmic-buck[1/2/5]-uses-gpio-dvs' optional
+ property is specified, the 'max8997,pmic-buck[1/2/5]-dvs-voltage'
+ property should specify atleast one voltage level (which would be a
+ safe operating voltage).
+
+ If either of the 'max8997,pmic-buck[1/2/5]-uses-gpio-dvs' optional
+ property is specified, then all the eight voltage values for the
+ 'max8997,pmic-buck[1/2/5]-dvs-voltage' should be specified.
+
+Optional properties:
+- interrupt-parent: Specifies the phandle of the interrupt controller to which
+ the interrupts from max8997 are delivered to.
+- interrupts: Interrupt specifiers for two interrupt sources.
+ - First interrupt specifier is for 'irq1' interrupt.
+ - Second interrupt specifier is for 'alert' interrupt.
+- max8997,pmic-buck1-uses-gpio-dvs: 'buck1' can be controlled by gpio dvs.
+- max8997,pmic-buck2-uses-gpio-dvs: 'buck2' can be controlled by gpio dvs.
+- max8997,pmic-buck5-uses-gpio-dvs: 'buck5' can be controlled by gpio dvs.
+
+Additional properties required if either of the optional properties are used:
+- max8997,pmic-ignore-gpiodvs-side-effect: When GPIO-DVS mode is used for
+ multiple bucks, changing the voltage value of one of the bucks may affect
+ that of another buck, which is the side effect of the change (set_voltage).
+ Use this property to ignore such side effects and change the voltage.
+
+- max8997,pmic-buck125-default-dvs-idx: Default voltage setting selected from
+ the possible 8 options selectable by the dvs gpios. The value of this
+ property should be between 0 and 7. If not specified or if out of range, the
+ default value of this property is set to 0.
+
+- max8997,pmic-buck125-dvs-gpios: GPIO specifiers for three host gpio's used
+ for dvs. The format of the gpio specifier depends in the gpio controller.
+
+Regulators: The regulators of max8997 that have to be instantiated should be
+included in a sub-node named 'regulators'. Regulator nodes included in this
+sub-node should be of the format as listed below.
+
+ regulator_name {
+ standard regulator bindings here
+ };
+
+The following are the names of the regulators that the max8997 pmic block
+supports. Note: The 'n' in LDOn and BUCKn represents the LDO or BUCK number
+as per the datasheet of max8997.
+
+ - LDOn
+ - valid values for n are 1 to 18 and 21
+ - Example: LDO0, LD01, LDO2, LDO21
+ - BUCKn
+ - valid values for n are 1 to 7.
+ - Example: BUCK1, BUCK2, BUCK3, BUCK7
+
+ - ENVICHG: Battery Charging Current Monitor Output. This is a fixed
+ voltage type regulator
+
+ - ESAFEOUT1: (ldo19)
+ - ESAFEOUT2: (ld020)
+
+ - CHARGER_CV: main battery charger voltage control
+ - CHARGER: main battery charger current control
+ - CHARGER_TOPOFF: end of charge current threshold level
+
+The bindings inside the regulator nodes use the standard regulator bindings
+which are documented elsewhere.
+
+Example:
+
+ max8997_pmic@66 {
+ compatible = "maxim,max8997-pmic";
+ interrupt-parent = <&wakeup_eint>;
+ reg = <0x66>;
+ interrupts = <4 0>, <3 0>;
+
+ max8997,pmic-buck1-uses-gpio-dvs;
+ max8997,pmic-buck2-uses-gpio-dvs;
+ max8997,pmic-buck5-uses-gpio-dvs;
+
+ max8997,pmic-ignore-gpiodvs-side-effect;
+ max8997,pmic-buck125-default-dvs-idx = <0>;
+
+ max8997,pmic-buck125-dvs-gpios = <&gpx0 0 1 0 0>, /* SET1 */
+ <&gpx0 1 1 0 0>, /* SET2 */
+ <&gpx0 2 1 0 0>; /* SET3 */
+
+ max8997,pmic-buck1-dvs-voltage = <1350000>, <1300000>,
+ <1250000>, <1200000>,
+ <1150000>, <1100000>,
+ <1000000>, <950000>;
+
+ max8997,pmic-buck2-dvs-voltage = <1100000>, <1100000>,
+ <1100000>, <1100000>,
+ <1000000>, <1000000>,
+ <1000000>, <1000000>;
+
+ max8997,pmic-buck5-dvs-voltage = <1200000>, <1200000>,
+ <1200000>, <1200000>,
+ <1200000>, <1200000>,
+ <1200000>, <1200000>;
+
+ regulators {
+ ldo1_reg: LDO1 {
+ regulator-name = "VDD_ABB_3.3V";
+ regulator-min-microvolt = <3300000>;
+ regulator-max-microvolt = <3300000>;
+ };
+
+ ldo2_reg: LDO2 {
+ regulator-name = "VDD_ALIVE_1.1V";
+ regulator-min-microvolt = <1100000>;
+ regulator-max-microvolt = <1100000>;
+ regulator-always-on;
+ };
+
+ buck1_reg: BUCK1 {
+ regulator-name = "VDD_ARM_1.2V";
+ regulator-min-microvolt = <950000>;
+ regulator-max-microvolt = <1350000>;
+ regulator-always-on;
+ regulator-boot-on;
+ };
+ };
+ };