diff options
Diffstat (limited to 'usr.sbin/mlxcontrol/mlxcontrol.8')
| -rw-r--r-- | usr.sbin/mlxcontrol/mlxcontrol.8 | 146 |
1 files changed, 146 insertions, 0 deletions
diff --git a/usr.sbin/mlxcontrol/mlxcontrol.8 b/usr.sbin/mlxcontrol/mlxcontrol.8 new file mode 100644 index 000000000000..0d8c546d1833 --- /dev/null +++ b/usr.sbin/mlxcontrol/mlxcontrol.8 @@ -0,0 +1,146 @@ +.\" +.\" Copyright (c) 2000 Michael Smith +.\" All rights reserved. +.\" +.\" Redistribution and use in source and binary forms, with or without +.\" modification, are permitted provided that the following conditions +.\" are met: +.\" 1. Redistributions of source code must retain the above copyright +.\" notice, this list of conditions and the following disclaimer. +.\" 2. The name of the author may not be used to endorse or promote products +.\" derived from this software without specific prior written permission +.\" +.\" THIS SOFTWARE IS PROVIDED BY THE AUTHOR ``AS IS'' AND ANY EXPRESS OR +.\" IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES +.\" OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. +.\" IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT, INDIRECT, +.\" INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT +.\" NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, +.\" DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY +.\" THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT +.\" (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF +.\" THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. +.\" +.Dd April 10, 2000 +.Dt MLXCONTROL 8 +.Os +.Sh NAME +.Nm mlxcontrol +.Nd Mylex DAC-family RAID management utility +.Sh SYNOPSIS +.Nm +.Aq command +.Op args +.Nm +status +.Op Fl qv +.Op Ar drive +.Nm +rescan +.Ar controller +.Op Ar controller ... +.Nm +detach +.Ar drive +.Op Ar drive ... +.Nm +detach +.Fl a +.Nm +check +.Ar drive +.Nm +config +.Ar controller +.Nm +help +.Ar command +.Sh DESCRIPTION +The +.Nm +utility provides status monitoring and management functions +for devices attached +to the +.Xr mlx 4 +driver. +.Pp +Controller names are of the form "mlxN" +where N is the unit number of the controller. +Drive names are of the form "mlxdN" +where N is the unit number of the drive. +Do not specify the path to a device node. +.Bl -tag -width rebuild +.It status +Print the status of controllers and system drives. +If one or more drives are specified, +only print information about these drives, +otherwise print information +about all controllers and drives in the system. +With the +.Fl v +flag, display much more verbose information. +With the +.Fl q +flag, do not print any output. +This command returns +0 if all drives tested are online, +1 if one or more drives are critical and +2 if one or more are offline. +.It rescan +Rescan one or more controllers for non-attached system drives +(e.g.\& drives that have been +detached or created subsequent to driver initialisation). +If the +.Fl a +flag is supplied, rescan all controllers in the system. +.It detach +Detach one or more system drives. +Drives must be unmounted +and not opened by any other utility for this command to succeed. +If the +.Fl a +flag is supplied, detach all system drives from the nominated controller. +.It check +Initiate a consistency check and repair pass on a redundant system drive +(e.g.\& RAID1 or RAID5). +The controller will scan the system drive and repair any inconsistencies. +This command returns immediately; +use the +.Ar status +command to monitor the progress of the check. +.It rebuild +Requires two arguments, +.Ar controller +and +.Ar physdrive +as specified in the +output of the +.Ar status +command. +All system drives using space on the physical drive +.Ar physdrive +are rebuilt, reconstructing all data on the drive. +Note that each controller can only perform one rebuild at a time. +This command returns immediately; use the +.Ar status +command to monitor the progress of the rebuild. +.It config +Print the current configuration from the nominated controller. +This command will be updated +to allow addition/deletion of system drives from a configuration +in a future release. +.It help +Print usage information for +.Ar command . +.El +.Sh AUTHORS +The +.Nm +utility was written by +.An Michael Smith Aq Mt msmith@FreeBSD.org . +.Sh BUGS +The +.Ar config +command does not yet support modifying system drive configuration. +.Pp +Error log extraction is not yet supported. |
